    Ground Improvement

    Resin Injection – Teretek®

    Overview

    Innovation in Ground Improvement

    Teretek® resin injection is used for ground improvement beneath existing structures. There are two primary applications for the technology, bearing capacity increase and

    Teretek® for ground improvement has been researched and developed to an extent that it can be designed to a high level of accuracy. Throughout its development, Mainmark have worked with international experts on the to test its performance across a wide range of geotechnical conditions.

    Mainmark works with client engineers to align the design requirements with achievable improvement targets. The design is determined by the initial soil properties and the desired target outcome for the overall performance of the structure. This influences the injection depths and extent of improvement required. Following the site application, the design is then validated using standard geophysical tests.

    Improvement Mechanism

    Teretek® resin injection strengthens the ground primarily through the densification of soil using an expanding polyurethane resin.

    As the resin expands, it densifies the surrounding soil and increases its strength and stiffness characteristics. In addition, several secondary benefits occur, including an increase in composite stiffness and particle cementation.

    The process involves the installation of small injection tubes, spaced evenly within the target improvement zone. At each point, resin is injected into the ground, forming a resin-soil matrix.

    Testing and Validation

    Teretek® resin injection projects are often within or in close proximity to existing structures and ongoing building operations. Following an engineering design, ground improvement targets are set, which are then validated through pre- and post-geotechnical tests.

    The Cone Penetrometer Test (CPT) is predominantly utilised in this context due to its precision in determining essential soil parameters like tip resistance, soil strength, and liquefaction potential. When operating beneath existing structures or in confined spaces, miniaturised CPT rigs become invaluable, navigating restrictive sites and basements.

    When required, the Direct-Push Cross-Hole (DPCH) test offers a broader perspective on larger projects, particularly for determining soil’s shear wave velocity.

    On simpler projects, the Dynamic Cone Penetrometer (DCP) can be utilised to assess bearing capacity.

    Resources

    Ground Improvement

    Resin Injection Ground Improvement Research Trials – Avondale and Bexley Red Zone Christchurch
    Use of expanding polyurethane resin to remediate expansive soil foundations
    Structure and properties of expanding polyurethane foam in the context of foundation remediation in expansive soil
    Resin injection as a ground improvement method

    Talk to an expert

    Contact us about your project

    Step 1

    Submit your enquiry using our online form. Include a brief message about the type of problem you are experiencing.

    Step 2

    One of our expert team members will be in touch to schedule a site inspection that suits you.

    Hidden
    Consent
    This field is for validation purposes and should be left unchanged.
    Mainmark

    © 2026 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.

    Mainmark Ground Engineering Pty Ltd
    ABN: 51 606 182 503

    ISO 9001
    ISO 14001
    ISO 45001

    Solutions

    Ground Improvement

    Subsidence Repair

    Re-Levelling

    Void Filling

    Slab Lifting

    Crack Wall Repair

    Sinking Floors

    Sinking Foundation Repair

    Underpinning Repairs

    Locations

    Adelaide

    Brisbane

    Canberra

    Hobart

    Melbourne

    New South Wales

    Perth

    Queensland

    South Australia

    Sydney

    Tasmania

    Townsville

    Victoria

    Western Australia

    Sectors

    Commercial

    Residential

    Infrastructure

    Mining

    Technologies

    Teretek®

    Terefil®

    JOG

    About Us

    Our team

    Careers

    Media & Press

    News

    Awards

    Contact

    Locations
    Mainmark Sydney

    169 Sailors Bay Rd, Northbridge NSW 2063

     

    Mainmark Melbourne

    Unit 8, 33 Rosalie Street, Springvale VIC 3171

    Mainmark South Australia

    19 Heath St, Lonsdale SA 5160

    Mainmark Queensland

    20 Computer Road, Yatala QLD 4207

    Mainmark Perth

    115 Excellence Dr, Wangara WA 6065

    Mainmark Tasmania

     4/11 McRorie Court Cambridge TAS 7170

    Privacy Policy

    Terms and Conditions

    Created by Codex

    YouTube
    Facebook
    LinkedIn
    Instagram