The problem
A commercial property under construction in Wollongong was experiencing water ingress in the basement, primarily caused by the high water table located approximately 2m above the basement slab.
The site was originally de-watered, however, when the de-watering system was
removed after the basement construction was completed, the water ingress
progressively increased. Water leakage was evident across the basement slab to the
wall junction, along the lift shaft wall and other spot locations.
Before the building’s mechanical services, electrical lift and car stackers could be
installed, the basement needed to be completely dry. In order to arrest the water
ingress, the source of the leakage needed to be located, which proved challenging due
to the latent ground conditions. The change in the hydraulic ground water gradient,
local to the basement’s perimeter, could not be easily identified.
Mainmark’s team was able to locate the source of the water, which was found to
be leaking through the combination secant piled and shotcrete wall system and the
basement slab. They were then able to successfully deliver a perimeter treatment that
intersected the interface between the wall system and the middle of the concrete slab.
The high water table, unrestricted ground water runoff movement, and potential
seepage via other un-tanked openings of the basement, particularly after heavy rain
events, were major considerations when selecting a suitable water stop solution for the
basement.
Given the time constraints and budget, Mainmark recommended using a specially
formulated acrylic gel, which provided a flexible membrane and sealant between the
basement concrete wall and original membrane previously installed at the rear of the
basement wall.
The solution
A long-term waterproofing solution that could seal the basement and eliminate water ingress was required for the construction to progress. The solution also needed to seal leaks at the joints, cracks and gaps in the concrete while diverting moisture away from the treated areas.
The Result
Prior to the project commencement, the Mainmark team successfully identified the source of water ingress behind the basement walls, despite limited information available to guide them to the source of the leaks. The water was then diverted into the building’s drainage system, preventing it from penetrating through the basement substrates. Mainmark injected a specially formulated acrylic gel to areas where leaking was evident. The acrylic-based hydro-structural resin was identified as the most appropriate solution due to the product’s ability to track the exact path of the water source, seal using a controllable reaction time, and ultra-low viscosity to seal behind the blind sides of the basement walls.
Once the preparatory drilling process is complete, the acrylic gel is easy to inject and boasts fast reaction and curing times. The variable setting time allows operators to adjust the speed of flow so the product is not diluted, allowing it to set behind and within the structure. The low viscous solution can also reemulsify up to 500 times, boasts excellent adhesive properties, and is able to seal wet and dry substrates and surfaces.
The client placed a high degree of trust in Mainmark for this basement project, as there was limited information available about where the leaks started and finished. For this reason, and to help ensure the project remained within budget, initially only areas with evident leaking in the basement areas were treated. The acrylic gel provided an efficient and effective solution for a problematic situation that alternatively could have required the client to undertake a very expensive, full curtain membrane of the substrate.
Resources
Project Resources & Downloads
Water Ingress in Building Basement Eliminated with Acrylic Gel
Download file
Please fill out this form to access this file.Next Project
Terefil® Used to Pre-Fill Pile Forms on High Rise Building Site
© 2024 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.
Mainmark Ground Engineering Pty Ltd
ABN: 51 606 182 503