    Project Profile V5083

    Railway Bridge Re-levelled and Re-supported

    Sub-industry
    Rail
    Problems
    Subsidence
    Location
    NSW
    Year
    2005
    Solutions
    Re-levelling
    Technology
    Uretek®

    The problem

    All four piers supporting the rail bridge at Henty in Southern NSW had subsided so that for safety, train speed over the bridge had been limited to a maximum of 40kph. With Uretek structural resin injection to strengthen the foundation ground, the bridge piers were re-supported and raised back to their exact design levels.

    The solution

    The objective was to re-level the rail lines and resupport the bridge piers quickly and efficiently to enable both passenger trains and goods trains to use the rail line safely, without the need to reduce speed.

    The Result

    The greatest possible load applied to the foundation to be strengthened enables the greatest possible compaction of the subgrade. In this case a heavy locomotive was used to provide a superimposed load as overburden resistance.

    The piers were shaped like an upside down T and were around 1200mm wide by the width of the bridge. The piers were founded at 1150mm deep. The National Rail Surveyor on site advised that the abutments at each end were unaffected, so they were used as the datum. Not only had all four piers subsided, but also this single track bridge was leaning to its western side.

    Structural expanding resins were injected directly under the pier footings. At first the pressure of the resins expanding compacted the foundation ground beneath the bridge piers.

    Then when maximum compaction had been achieved, the pressure was exerted upwards, lifting the piers, the bridge structure and rails.

    In a single shift, the bridge was re-levelled, raising the four piers by as much as 40mm and correcting the differential settlement across the track by as much as 20mm. Rail traffic was able to resume safe use of the line at normal speeds, just 30 minutes later.

    Resources

    Project Resources & Downloads

    Railway Bridge Re-levelled and Re-supported
    Teretek®
    Next Project

    Airport Runway Rehabilitation

    Mainmark

    © 2026 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.

    Mainmark Ground Engineering Pty Ltd
    ABN: 51 606 182 503

    ISO 9001
    ISO 14001
    ISO 45001

    Solutions

    Ground Improvement

    Subsidence Repair

    Re-Levelling

    Void Filling

    Slab Lifting

    Crack Wall Repair

    Sinking Floors

    Sinking Foundation Repair

    Underpinning Repairs

    Locations

    Adelaide

    Brisbane

    Canberra

    Hobart

    Melbourne

    New South Wales

    Perth

    Queensland

    South Australia

    Sydney

    Tasmania

    Townsville

    Victoria

    Western Australia

    Sectors

    Commercial

    Residential

    Infrastructure

    Mining

    Technologies

    Teretek®

    Terefil®

    JOG

    About Us

    Our team

    Careers

    Media & Press

    News

    Awards

    Contact

    Locations
    Mainmark Sydney

    169 Sailors Bay Rd, Northbridge NSW 2063

     

    Mainmark Melbourne

    Unit 8, 33 Rosalie Street, Springvale VIC 3171

    Mainmark South Australia

    19 Heath St, Lonsdale SA 5160

    Mainmark Queensland

    20 Computer Road, Yatala QLD 4207

    Mainmark Perth

    115 Excellence Dr, Wangara WA 6065

    Mainmark Tasmania

     4/11 McRorie Court Cambridge TAS 7170

    Privacy Policy

    Terms and Conditions

    Created by Codex

    YouTube
    Facebook
    LinkedIn
    Instagram