    Project Profile N15W057

    Retaining Walls Stabilisation

    Sub-industry
    House
    Problems
    Subsidence
    Location
    NSW
    Year
    2014
    Solutions
    Ground Improvement
    Technology
    Other, Permeation Grouting

    The problem

    Built on loose sands, a residential property in the Sydney suburb of Bondi was at significant risk of damage or even collapse. The existing retaining wall, built 800mm from the property’s rear façade, had failed and was experiencing significant rotational displacement. The house footings had also settled unevenly due to loose sands below. The neighbouring five-storey apartment block was at risk too, as another retaining wall was located on the boundary line. If this wall collapsed, the driveway would have been destabilised, along with the footings of the building.

    Due to the close proximity of the adjacent structures, constructing a conventional concrete retaining wall was not feasible. This necessitated excavation up to the property’s boundary. Mainmark was appointed to solidify loose sand and prevent it from falling in on the rear excavation, allowing a new retaining wall to be safely constructed. Over 25 days, a total of 197 columns were inserted at various depths. The columns were used to support both the eastern boundary and north façade from further settlement or movement.

    The solution

    There were three key objectives for the project. First, it was essential to retain the sandy fill mass before the excavation. Second, the rear retaining wall needed to be moved to create a space for a paved courtyard. Third, ground improvement was required to arrest the movement of the house footings, enabling repairs to be made to the brickwork above.

    The Result

    ACOR Consultants chose Mainmark’s Permeation Grouting solution for the project. Designed to strengthen sand and gravels, and repair structural formations at depths as great as 60m, Permeation Grouting produces a solidified mass to support higher loads and fill voids in the soil. It offers a safe solution for stabilising ground when excavation is required adjacent to another building or structure.

    Microfine cement was grouted into loose sands, providing temporary support to allow excavation for a new retaining wall at the rear of the property and stabilisation of boundary wall. 110 columns were inserted to a depth of 2000mm on the eastern boundary to solidify the loose sands under the footpath and prevent further settlement.

    A further 72 columns were inserted to a depth of 4500mm to help retain the mass of loose sand from falling in on the excavation, and 15 additional columns were used to support the north façade. Furthermore, ground anchors were formed by pneumatically driving threaded steel drill rods 3m to 6m into the sandy soils. The chemical ground anchors restrained the cement permeated soil block from rotating into the excavation. An expanding PUR was injected through the hollow centres of the rods and a ‘bulb’ of very hard-setting resin formed the anchorage deep into the sand.

    The anchors were successfully tested after 24 hours to a withdrawal-resistance strength of 4.4 ton (4.4kn), and formed the foundation for a retaining structure to be constructed. According to Mitchell Bell from ACOR Consultants, “Mainmark’s outstanding solution stabilised the house to prevent further settlement and facilitated the safe construction of a new retaining wall.”

    “In addition, Mainmark was able to offer an alternative solution in the event of unfavourable subsoil conditions being encountered during the project, thus minimising risk.” “I would happily recommend Mainmark and we have continued to work with the company on subsequent projects.”

    Resources

    Project Resources & Downloads

    Retaining Walls Stabilisation
    Next Project

    Strengthen Rail Index Machine Slab

    Mainmark

    © 2026 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.

    Mainmark Ground Engineering Pty Ltd
    ABN: 51 606 182 503

    ISO 9001
    ISO 14001
    ISO 45001

    Solutions

    Ground Improvement

    Subsidence Repair

    Re-Levelling

    Void Filling

    Slab Lifting

    Crack Wall Repair

    Sinking Floors

    Sinking Foundation Repair

    Underpinning Repairs

    Locations

    Adelaide

    Brisbane

    Canberra

    Hobart

    Melbourne

    New South Wales

    Perth

    Queensland

    South Australia

    Sydney

    Tasmania

    Townsville

    Victoria

    Western Australia

    Sectors

    Commercial

    Residential

    Infrastructure

    Mining

    Technologies

    Teretek®

    Terefil®

    JOG

    About Us

    Our team

    Careers

    Media & Press

    News

    Awards

    Contact

    Locations
    Mainmark Sydney

    Level 7/124 Walker Street, North Sydney NSW 2060

     

    Mainmark Melbourne

    Unit 8, 33 Rosalie Street, Springvale VIC 3171

    Mainmark South Australia

    19 Heath St, Lonsdale SA 5160

    Mainmark Queensland

    20 Computer Road, Yatala QLD 4207

    Mainmark Perth

    115 Excellence Dr, Wangara WA 6065

    Mainmark Tasmania

     4/11 McRorie Court Cambridge TAS 7170

    Privacy Policy

    Terms and Conditions

    Created by Codex

    YouTube
    Facebook
    LinkedIn
    Instagram