    Teretek® Re-Levels Wash Plant Slab & Restores Drainage Performance

    Sub-industry
    Wash Plant
    Problems
    Out-of-level Concrete
    Location
    VIC
    Year
    2026
    Solutions
    Re-levelling
    Technology
    Teretek®

    A materials recycling facility in Victoria was experiencing differential settlement beneath the reinforced concrete slab supporting its wash plant. The movement had disrupted the designed drainage falls, causing water and slurry to pond throughout the operating area. The facility operator required a solution to improve the supporting ground, re-support and lift the slab, and restore effective drainage while retaining the existing wash plant infrastructure and minimising operational disruption.

    Problem

    The approximately 150 m² slab supporting Wash Plant No. 1 and its water tank had settled unevenly, creating low points that prevented water and slurry from draining effectively towards the catchment pits.

    The loss of effective drainage was causing water and slurry to continually accumulate throughout the active wash plant area. In addition to creating an ongoing operational issue for the facility, the trapped water was saturating the supporting soils and contributing to further settlement beneath the heavily loaded slab.

    Site investigations identified pockets of voiding below the slab. The reinforced concrete slab also varied considerably in thickness across the treatment area and became substantially thicker near the adjoining water pit, adding complexity to the drilling and injection works.

    Solution

    To address the settlement and loss of support beneath the wash plant, Mainmark developed a targeted Teretek® resin injection program.

    Injection points were installed across the treatment area at approximately 1.2 m intervals. Teretek® expanding polyurethane resins were injected at depths of up to 3.5 m, with deeper injections concentrated beneath the areas of greatest settlement.

    As the resin expanded, it filled voids, displaced trapped subsurface water and compacted the surrounding soils to improve ground bearing performance. Once support had been re-established, controlled injections continued to lift the slab and restore the required drainage falls.

    Movement was continuously monitored using laser levelling equipment and receivers positioned on the slab and tank support columns. Before the final injection stage, the water tank was refilled, enabling Mainmark to assess the slab’s response and complete the treatment while the structure was under its operational load.

    Result

    Mainmark injected approximately 3,700 kg of Teretek® material over four working days, filling subsurface voids, consolidating the supporting ground and achieving controlled level recovery across the treatment area.

    Measurements taken beneath the tank support columns recorded localised lift of up to approximately 68 mm. The final injections were completed with the water tank at full capacity, allowing the treated area to be assessed under operational load.

    The works improved slab alignment and restored effective drainage falls towards the drainage area, reducing water and slurry ponding around the wash plant. The existing infrastructure remained in place throughout the works, avoiding the disruption and cost associated with removing the tank or reconstructing the reinforced concrete slab.

     

    Resources

    Project Case Study

    Teretek® Re-Levels Wash Plant Slab & Restores Drainage Performance
    Need help?

    Need help with a project? Contact us today.

    Next Project

    Slab Lifting & Re-support for a Warehouse End-of-Lease Make-good

    Mainmark

    © 2026 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.

    Mainmark Ground Engineering Pty Ltd
    ABN: 51 606 182 503

    ISO 9001
    ISO 14001
    ISO 45001

    Solutions

    Ground Improvement

    Subsidence Repair

    Re-Levelling

    Void Filling

    Slab Lifting

    Crack Wall Repair

    Sinking Floors

    Sinking Foundation Repair

    Underpinning Repairs

    Locations

    Adelaide

    Brisbane

    Canberra

    Hobart

    Melbourne

    New South Wales

    Perth

    Queensland

    South Australia

    Sydney

    Tasmania

    Townsville

    Victoria

    Western Australia

    Sectors

    Commercial

    Residential

    Infrastructure

    Mining

    Technologies

    Teretek®

    Terefil®

    JOG

    About Us

    Our team

    Careers

    Media & Press

    News

    Awards

    Contact

    Locations
    Mainmark Sydney

    Level 7/124 Walker Street, North Sydney NSW 2060

     

    Mainmark Melbourne

    Unit 8, 33 Rosalie Street, Springvale VIC 3171

    Mainmark South Australia

    19 Heath St, Lonsdale SA 5160

    Mainmark Queensland

    20 Computer Road, Yatala QLD 4207

    Mainmark Perth

    115 Excellence Dr, Wangara WA 6065

    Mainmark Tasmania

     4/11 McRorie Court Cambridge TAS 7170

    Privacy Policy

    Terms and Conditions

    Created by Codex

    YouTube
    Facebook
    LinkedIn
    Instagram