    Targeted Ground Improvement Addresses Settlement Beneath Six Silo Slabs

    Sub-industry
    Silos
    Problems
    Subsidence
    Location
    SA
    Year
    2026
    Solutions
    Re-levelling
    Technology
    Teretek®

    Eighteen silos used to store feedstock at a farm in South Australia were supported on six separate concrete slabs showing varying degrees of subsidence. The client was concerned that further movement could create a safety issue and force some silos out of service. A targeted solution was required to improve ground support beneath the slabs and recover levels where practical, with priority given to the areas of greatest concern.

    Problem

    The six concrete slabs formed the load-bearing bases for the silo group. Varying degrees of subsidence had developed across all slabs, raising concern about the adequacy of ground support beneath the footings and the potential for further movement under silo loads.

    The client wanted to keep the silos in service for feedstock storage. Continued settlement therefore presented a potential loss of storage capacity as well as a safety concern.

    The works needed to improve support beneath the existing slab footings and address the sections with the greatest need for treatment. Areas of secondary importance also needed to be identified for subsequent review.

    Solution

    Mainmark undertook a site inspection and measured levels across all six slabs to establish the pattern and relative extent of subsidence. Site maps were then prepared to distinguish priority areas for ground support from areas of secondary importance.

    A targeted Teretek® resin injection program was developed around the mapped priorities. The injection approach specified holes 16mm in diameter approximately 1.2 m centres along the affected footings.

    Teretek® resin was injected beneath the slab footings to fill voids and improve the density and bearing capacity of the supporting soils. Treatment extended to a depth of approximately 1m.

    The works improved support beneath the treated sections of the slabs and achieved localised re-levelling where the footings responded to the injection process.

    Result

    Mainmark injected 731 kg of Teretek® resin over two days, providing improved ground support beneath treated sections of all six slabs.

    Settled sections of the slabs were re-levelled, reducing the level differences caused by subsidence.

    The works improved support beneath the foundations carrying the 18 silos and helped reduce the risk of further settlement in the treated areas. The targeted treatment addressed the priority areas identified during the site inspection, helping to protect the existing silo assets and support their continued use for feedstock storage.

     

    Resources

    Project Case Study

    Targeted Ground Improvement Addresses Settlement Beneath Six Silo Slabs
    Need help?

    Need help with a project? Contact us today.

    Next Project

    Teretek® Resin Injection Restores Support Beneath a Settled Depot Hardstand

    Mainmark

    © 2026 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.

    Mainmark Ground Engineering Pty Ltd
    ABN: 51 606 182 503

    ISO 9001
    ISO 14001
    ISO 45001

    Solutions

    Ground Improvement

    Subsidence Repair

    Re-Levelling

    Void Filling

    Slab Lifting

    Crack Wall Repair

    Sinking Floors

    Sinking Foundation Repair

    Underpinning Repairs

    Sectors

    Commercial

    Residential

    Infrastructure

    Mining

    Technologies

    Teretek®

    Terefil®

    JOG

    About Us

    Our team

    Careers

    Media & Press

    News

    Awards

    Contact

    Privacy Policy

    Terms and Conditions

    Created by Codex

    YouTube
    Facebook
    LinkedIn
    Instagram