Get a FREE Quote Call Us

Search

If you cant find what you’re after please don’t hesitate to contact us.

Select Region

Please select the global region website you'd like to view.

Asia
Japan

Get a FREE Quote

Submit your enquiry using the online form with a brief description of the issue. A Mainmark expert will be in touch within 24–48 hours (excluding weekends and public holidays).

After clicking Submit, you’ll receive an email with the next steps—please check your inbox and spam folder.

Hidden
Photos or reports of issues (optional)
Drop files here or
Max. file size: 16 MB.
    Consent
    This field is for validation purposes and should be left unchanged.

    Project Profile N20GW272

    Teretek® Preserves Foundations of Large Heritage Listed Building

    Sub-industry
    Heritage
    Problems
    Ground Improvement
    Location
    NSW
    Year
    2020
    Solutions
    Ground Improvement
    Technology
    Teretek®

    The problem

    A heritage listed former grain storage facility in Sydney was being prepared to undergo building improvements to help protect and preserve the site for future use. Geotechnical engineers had identified ground weakness beneath the large 75m x 50m brick and stone building and the client sought to proactively strengthen the ground beneath the building’s footings as a precaution to preserve the heritage structure for future generations.

    Dynamic cone penetration (DCP) tests that were undertaken by the engineers had determined that the existing soils beneath the footings were of low compressive strength at approx. 140kPa. Mainmark was engaged to develop a concept solution to improve the ground strength to greater than 200kPa by injecting Mainmark’s Teretek resin injection solution to specific locations, depths and volumes.

    Before commencing the full scope of works, a small on site trial was conducted using Mainmark’s Teretek resin injection solution to verify that the concept design would achieve the desired level of ground strength. After the trial proved successful, Mainmark was asked to complete the ground strengthening works to the entire footprint of the building.

    As the structure was not experiencing any settlement, it was important that the Teretek resin injection did not lift the building in any way. The site was also adjacent to pedestrian footpaths and services which required special consideration to avoid impact on access and the environment.

    The solution

    Mainmark was required to provide a ground improvement solution to increase the bearing capacity of the soil beneath the building’s foundations from approx.140kPa to at least 200kPa with the overarching objective being to provide additional support for the building.

    The Result

    The building’s foundation ground was strengthened using Teretek, an engineered resin injection solution that improves and consolidates weak soils and delivers exceptional ground strengthening.

    In the design development phase, Mainmark worked in collaboration with the engineers on a concept solution detailing the injection pattern, depths and volumes of Teretek material to be placed.

    Prior to undertaking the full scope of work, Mainmark conducted a Teretek trial on site to ensure the solution would achieve the required 200kPa ground strengthening. The trial was conducted in two strategic 2.5Lm areas, representing the whole site beneath the building’s foundations, with engineers closely reviewing DCP tests that were taken after each Teretek injection to check the strength of the treated soil and sub-surface soil layers.

    After engineers confirmed the trials had been effective, Mainmark proceeded to inject Teretek around the building’s entire 250Lm perimeter footings, every 1m at depths of 3m, 2.5m and 2m. Due to the size of the solid brick footings, which measured 600mm in width, Mainmark injected Teretek to both sides of the footings to effectively address the ground weaknesses that were identified in the geotechnical report, improve the soil in the full footing width and avoid rotating the footing from a one-sided treatment.

    Teretek is an advanced solution for ground improvement and re-levelling structures that, compared to other techniques, is cost effective, non-invasive and has no detrimental effects on the environment.

    The Teretek injection process was completed in just 8 days with the client impressed with Teretek’s ability to deliver significant ground improvement for such a large heavy structure. This was achieved with very little impact on the surrounding pavements and building functionality during the works.

    Upon completion, the site’s contractors engaged Mainmark to undertake further additional ground improvement works to support the building’s internal columns. The site’s contractors were also pleased with how a relatively small investment in the Teretek pre-works trial was able to give the engineering team greater confidence in the process and validation to proceed with a large-scale ground improvement project.

    Resources

    Project Resources & Downloads

    Teretek® Preserves Foundations of Large Heritage Listed Building
    Teretek®
    Next Project

    Earthquake Damaged Home Re-Levelled Using Teretek® and JOG Computer Controlled Grouting

    Mainmark

    © 2026 The Mainmark group of companies. ‘Mainmark®’, ‘Terefil®’, ‘Terefirm®’ and ‘Teretek®’ are trademarks of the Mainmark group of companies.

    Mainmark Ground Engineering Pty Ltd
    ABN: 51 606 182 503

    ISO 9001
    ISO 14001
    ISO 45001

    Solutions

    Ground Improvement

    Subsidence Repair

    Re-Levelling

    Void Filling

    Slab Lifting

    Crack Wall Repair

    Sinking Floors

    Sinking Foundation Repair

    Underpinning Repairs

    Locations

    Adelaide

    Brisbane

    Canberra

    Hobart

    Melbourne

    New South Wales

    Perth

    Queensland

    South Australia

    Sydney

    Tasmania

    Townsville

    Victoria

    Western Australia

    Sectors

    Commercial

    Residential

    Infrastructure

    Mining

    Technologies

    Teretek®

    Terefil®

    JOG

    About Us

    Our team

    Careers

    Media & Press

    News

    Awards

    Contact

    Locations
    Mainmark Sydney

    Level 7/124 Walker Street, North Sydney NSW 2060

     

    Mainmark Melbourne

    Unit 8, 33 Rosalie Street, Springvale VIC 3171

    Mainmark South Australia

    19 Heath St, Lonsdale SA 5160

    Mainmark Queensland

    20 Computer Road, Yatala QLD 4207

    Mainmark Perth

    115 Excellence Dr, Wangara WA 6065

    Mainmark Tasmania

     4/11 McRorie Court Cambridge TAS 7170

    Privacy Policy

    Terms and Conditions

    Created by Codex

    YouTube
    Facebook
    LinkedIn
    Instagram